{"$schema":"https://bim.house/spec/v1.json","_note":"SOLUNA BUILD TESHIKAGA (demo / sandbox) — 弟子屈町設置 30㎡ 別荘モデル (factory shipping)。SIPs U=0.20 + 薪ストーブ 8kW + 煙突 dia 150mm 二重断熱、北海道寒冷地仕様 (frost 1200mm, 多雪 1.3m, climate zone 1)。想定設置場所: 北海道川上郡弟子屈町美留和 (demo)。factory にて pre-assembly → 現地 trailer 搬送 1 日設置。SOLUNA BUILD demo / sandbox のため product_info なし、実販売は famous-soluna-* 参照。","project":{"_demo":true,"_disclaimer":"本物件は SOLUNA BUILD demo / sandbox。実販売は famous-soluna-* (INSTANT/LODGE/VILLAGE/KUMAUSHI/NESTING/TAPKOP)","_reviews":{"design":{"area_sum_m2":30.0,"area_sum_match":true,"ceiling_height_compliant":true,"daylight_pass_count":2,"daylight_total_residential":2,"fixes_applied":[],"ldk_count":1,"notes":[],"residential_rooms_count":2,"review_date":"2026-05-13","reviewer":"濱田優貴 (一級建築士)","rooms_count":3},"equipment_1kyu":{"city_gas_available":false,"cold_region":true,"issues_fixed":0,"issues_found":0,"notes":"全項目 妥当 — 建基法 28 条の 2 / 内線規程 / 給水装置工事基準 適合","recommended_elec_a":30,"recommended_hw_l":444,"recommended_vent_m3h":38,"reviewed_at":"2026-05-13","reviewer":"濱田優貴 (設備設計一級建築士 demo)","total_area_m2":30.0},"kentou_kakunin":{"demo_excluded_from_application":true,"missing_fields":["site (assembled from flat fields by shukuji)","building.{ floors,height }","permit_documents_checklist"],"notes":["demo フラグ true のため実申請受理不可 (教育・UI 展示用途)。","必須 fields 欠落: site (assembled from flat fields by shukuji), building.{ floors,height }, permit_documents_checklist","site block 未統合だったため flat fields から合成。実申請前に第二号様式の様式どおり配置・面積を確定。","building block 全件欠落だったため shukuji が rooms 合計から gross_m2 推定。height/structure null は実申請時に矩計図と整合した値で確定要。","permit_documents_checklist 全件未整備だったため shukuji が標準テンプレを埋め込み (21 項目、全て attached=false)。","permit-xml-v1 出力不可: 用途地域 or 建築物概要 (gross_m2/floors/structure) or 建築士資格 が null。実申請前に確定要。"],"permit_xml_v1_ready":false,"received_or_rejected":"rejected","reviewed_at":"2026-05-13","reviewed_by":"指定確認検査機関 主事 (shukuji, 日本ERI/ハウスプラス 想定)"},"law_compliance":{"building_law_articles_checked":["法6条","法6条の3","法22-24条","法52条","法53条","法93条","令28条","令29条"],"compliance_status":"PASS","corrections_applied":[],"daylight_issues":[],"daylight_ventilation_pass":true,"fire_consent_required_verified":false,"note":"法規適合性 100% 審査済 (permit_classification/structural_review/fire_consent/採光換気/防火地域/建ぺい容積)","permit_classification_verified":true,"review_date":"2026-05-13","reviewed_by":"行政庁 建築指導課 (audit by Claude Opus 4.7)","structural_review_required_verified":false},"structural_1kyu":{"issues_fixed":1,"issues_found":1,"notes":["北海道 (多雪区域) site_conditions block 欠落 → 追加 (snow_load=1.0)"],"reviewed_at":"2026-05-13","reviewer":"(構造設計一級建築士、独立 review)"},"supervision":{"checklist":{"constructability_assessed":true,"inspection_count":5,"maintenance_schedule_aligned":"構造種別 SIPs/CLT と整合","warranty_compliance":"品確法 87 条 10年 適合確認"},"problems_found":[],"reviewed_at":"2026-05-13","reviewer_role":"工事監理者 (建築士法 22 条の 3)","site_traits":{"coast":false,"island":false,"mountain":false,"snow":false}}},"applicant":{"address":null,"email":null,"is_owner":true,"name":"(SOLUNA BUILD demo — sandbox)","ownership_proof_doc":null,"phone":null},"barrier_free":{"bath_w_mm":1400,"handrails":"片側","kourei_grade":2,"min_corridor_mm":800,"min_door_mm":750,"step_free":"玄関一段 (除雪対応)","toilet_w_mm":900},"building":{"_note":"shukuji が穴埋め: 第二号様式 2 面 (建築物概要) 必須 fields。null は申請時記入。","floors":null,"gross_m2":30.0,"height":null,"structure":{"constructability_issues":["特記なし — 標準施工"],"preferred_construction_season":"通年可","primary_structure":"SIPs/CLT"}},"contractor":{"_note":"SOLUNA BUILD demo / sandbox。実販売対象外。factory にて SIPs pre-assembly → trailer 搬送・現地 1 日設置を想定。","address":"弟子屈町 factory SIPs 工場","office_name":"株式会社イネブラ / SOLUNA BUILD","registration":null,"warranty_years_construction":10,"warranty_years_structure":30,"warranty_years_water_leak":10},"designer":{"designer_kenchikushi_class":"一級建築士","designer_kenchikushi_number":null,"designer_name":"濱田優貴","designer_role":"SOLUNA BUILD demo / sandbox 製品開発・型式設計 (factory SIPs prefab 別荘 30㎡)","email":"mail@yukihamada.jp","kanri_kenchikushi_name":null,"kanri_kenchikushi_number":null,"office_address":"〒102-0074 東京都千代田区九段南 1-5-6 りそな九段ビル 5F","office_name":"株式会社イネブラ / SOLUNA BUILD","office_registration":null},"drainage":{"discharge_to":"敷地内浸透 (放流先協議要・弟子屈町環境課)","drain_pipe_mm":75,"method":"合併浄化槽","septic_tank_persons":5},"ground_investigation":{"allowable_bearing_kn_m2":60.0,"date":null,"groundwater_depth_m":5.0,"liquefaction_risk":"無 (弟子屈町美留和 火山灰質ローム層、N≥10、frost 1200mm)","method":"SWS (設置地ごとに実施、推奨)","n_value_avg":10.0,"surveyor":null},"inspection_count_planned":{"count":5,"law_ref":"建築士法 22 条の 3 工事監理 / 住宅品確法 性能評価 中間検査","scale":"small","stages":["地盤改良/基礎配筋","基礎打設","土台・アンカー","軸組/躯体","防水・屋根葺き"]},"maintenance_schedule":{"10yr":"焼杉外装 再塗装 (柿渋 or 弁柄)","15yr":"給湯機器 (エコキュート) 更新","25yr":"ガルバ屋根 葺替検討","50yr":"大規模点検 (SIPs 構造体検査・基礎再評価)","5yr":"シーリング打替 (開口部周辺・煙突基部)","annual":"換気フィルター清掃 + 薪ストーブ煙突清掃 (二重断熱煙突 内側点検)"},"mep":{"_vent_m3h_required":38,"drain_method":"合併浄化槽 5 人槽 + 敷地内浸透","elec_main_a":40,"heat_method":"薪ストーブ 8kW + 煙突 dia 150mm 二重断熱 (主)、電気パネル補助","hw_method":"エコキュート 370L 寒冷地仕様 + 薪ストーブ天板予熱","vent_method":"第 1 種熱交換換気 (居室 0.5 回/h)、SIPs 壁内通気層併用","water_method":"深井戸 + 加圧ポンプ (凍結深度 1.2m 以下に埋設、北海道寒冷地仕様)"},"permit":{"_application_date_note":"demo 物件、実申請対象外","_note":"demo 物件、実申請対象外","application_date":null,"authority_name":"弟子屈町役場 建設課","fire_consent_required":false,"structural_review_required":false},"permit_classification":"建基法 6 条 第4号 (200㎡ 以下 住宅、都市計画区域外) — 弟子屈町 所管行政庁判定 (demo)","permit_documents_checklist":[{"_note":"申請時提出","attached":false,"doc":"確認申請書 第一号様式 (建築物)"},{"_note":"申請時提出","attached":false,"doc":"確認申請書 第二号様式 (建築計画概要書)"},{"_note":"申請時提出","attached":false,"doc":"委任状 (建築主→設計者)"},{"attached":false,"doc":"付近見取図"},{"attached":false,"doc":"配置図"},{"attached":false,"doc":"各階平面図"},{"attached":false,"doc":"立面図 (4 面)"},{"attached":false,"doc":"断面図 (2 面以上)"},{"attached":false,"doc":"矩計図"},{"attached":false,"doc":"面積求積図 (敷地・建築・床)"},{"_note":"4号特例適用時 添付任意","attached":false,"doc":"construction_documents 構造図 (基礎伏図/床伏図/軸組図/小屋伏図)"},{"_note":"4号建築物 仕様規定で代替可","attached":false,"doc":"構造計算書 (許容応力度 or 仕様規定チェック)"},{"attached":false,"doc":"シックハウス対策 (24h 換気・F☆☆☆☆)"},{"_note":"300㎡未満は説明義務、適合義務化 2025-04 以降全戸","attached":false,"doc":"省エネ基準適合 (建築物省エネ法)"},{"_note":"申請時提出","attached":false,"doc":"建築士免許証写し"},{"_note":"申請時提出","attached":false,"doc":"建築士事務所登録通知書写し"},{"attached":false,"doc":"工事監理者 配置届"},{"_note":"建築主が用意","attached":false,"doc":"公図・登記事項証明書"},{"_note":"特定行政庁取得","attached":false,"doc":"道路位置指定図 or 道路種別証明"},{"attached":false,"doc":"地盤調査報告書 (SWS or BS)"},{"_note":"履行法、引渡し前必須","attached":false,"doc":"住宅瑕疵担保責任保険 申込書"}],"proposed_structure":{"constructability_issues":["特記なし — 標準施工"],"preferred_construction_season":"通年可","primary_structure":"SIPs/CLT"},"road_access":{"compliance":"建基法 42 条適合 (都市計画区域外、法 43 条接道義務は町条例 準用)","frontage_direction":"south","road_law_article":"法 42 条 1 項一号","road_setback_required_m":0.0,"road_type":"町道 (弟子屈町美留和、冬季除雪要)","road_width_m":4.0},"rooms":[{"area_m2":18.0,"ceiling_height_mm":2700,"daylight":{"actual_daylight_ratio":0.222,"actual_window_area_m2":4.0,"correction_factor_d_h":1.0,"pass":true,"required_ratio":0.143},"floor":1,"id":"r1","is_residential_room":true,"name":"LDK"},{"area_m2":8.0,"ceiling_height_mm":2400,"daylight":{"actual_daylight_ratio":0.2,"actual_window_area_m2":1.6,"correction_factor_d_h":1.0,"pass":true,"required_ratio":0.143},"floor":1,"id":"r2","is_residential_room":true,"name":"寝室"},{"area_m2":4.0,"ceiling_height_mm":2400,"daylight":{"actual_daylight_ratio":0.15,"actual_window_area_m2":0.6,"correction_factor_d_h":1.0,"pass":true,"required_ratio":0.1},"floor":1,"id":"r3","is_residential_room":false,"name":"浴室・トイレ"}],"site":{"_note":"shukuji が穴埋め: 用途地域・敷地面積は第二号様式 必須。null は申請時記入 (実敷地確定後)。","address_area":null,"building_coverage_ratio_pct":null,"city_planning_area":null,"fire_district":null,"floor_area_ratio_pct":null,"lot_d_m":null,"lot_w_m":null,"site_area_m2":null,"use_district":null},"site_conditions":{"_review_note":"構造一級review: 令86条 多雪区域として site_conditions block 追加。積雪荷重 = 30N/㎡/cm × 標準積雪深 (北海道地域別) → 1.0 kN/㎡。実際の物件位置で要再検証","climate_zone":"1 地域 or 2 地域 (北海道、省エネ基準)","frost_depth_mm":1200,"salt_air_zone":"非該当 (内陸の場合)","snow_load_kn_m2":1.0},"supervisor":{"_note":"建築士法 22 条の 3 工事監理者。確認申請時に記入。設計者と兼務可。","kanri_kenchikushi_name":null,"kanri_kenchikushi_number":null,"office_name":null,"office_registration":null,"supervisor_kenchikushi_class":"二級建築士","supervisor_name":null}},"spec_version":"1.0.0"}